CN565X Pneumatic Coil Nail Gun
Product Description
Product Overview: CN565X Pneumatic Coil Nail Gun The CN565X Pneumatic Coil Siding Nailer is a top of the line professional grade pneumatic siding nailer. The CN565X is used for siding, fencing, exterior trim, furring, and strapping jobs.Adjustable depth guide sets nails to desired depths. Lightweight magnesium housing design for durability. Soft rubber foot prevents damage. Tool-free adjustable exhaust conveniently directs exhaust away from the user. ● 10 times/second rapid fire. ● Lightweight aluminum design for durability. ● Soft rubber foot helps to prevent damage to softer woods. ● Adjustable exhaust conveniently directs exhaust away. |
Model: | CN565X Pneumatic Coil Nail Gun |
Air Tool Type: | Air Nailer |
Tools Product Type: | Air Tool |
Tool Diamensions: | 315mmx128mmx306mm(12-7/16"x5"x12-1/16") |
Net Tool Weight: | 3.67kgs(8.07lbs) |
Body Material: | Aluminum Body |
Operate Pressure: | 70-120psi(5-8.3bar) |
Load Capcity | 225-300 nails |
Fasteners Type: | 15 Degree flat wire coil nails |
15 Degree Flat plastic sheet collated nails | |
Fasteners Head Diameter: | 0.197"(5.0mm)-0.236"(6.0mm) |
Fasteners Shank Diameter: | 0.083"(2.1mm)-0.099"(2.5mm) |
Fasteners Length: | 1-1/4"(32mm)-2-1/2"(65mm) |
Fasteners Shank Type: | Smooth,Screw,Ring |
15 Degree flat wire coil nails Head Diameter: 0.197"(5.0mm)-0.236"(6.0mm) Shank Diameter: 0.083"(2.1mm)-0.099"(2.5mm) Nail Length: 1-1/4"(32mm)-2-1/2"(65mm) Shank Type: Smooth ,Screw ,Ring, | 15 Degree Flat plastic sheet collated nails Head Diameter: 0.197"(5.0mm)-0.236"(6.0mm) Shank Diameter: 0.083"(2.1mm)-0.099"(2.5mm) Nail Length: 1-1/4"(32mm)-2-1/2"(65mm) Shank Type: Smooth ,Screw ,Ring, |
Compatible grip handle with 15 degree wire and plastic inserted coil nails.
10 times/second rapid fire.
Light weight and compact for easy maneuverability and extend use.
Sheet collated nails without any adjustment.
Depth adjustable for countersink and flush nail drive.
Non-Marring tip protects working surface from damage.
Decking Siding.
Siding (Hardboard and cement).
Sheathing,Fencing.
Roofing decking and exterior deck and trim.
Furring and strapping.
No. | Symptom | Problems | Solutions | |
1.1 | Air Leak | Air leak in the cylinder cap when tools don't work | 1.Loose head valve piston seal or o-rings . | Check and replace the head valve piston set |
2.Worn or damaged o-ring or cylinder cap gasket under cylinder cap | Check and replace o-ring or cylinder cap gasket under the cylinder cap | |||
1.2 | Air leak in Trigger area when tools don't work | 1.Damaged o-ring in trigger valve | Check and replace o-ring | |
2.Damaged o-ring in trigger valve stem | Check and replace o-ring | |||
3.Dirt in the trigger valve | Check and clean the trigger valve | |||
1.3 | Air leak in cylinder cap when tools are working | 1.Damaged head valve piston o-rings | Check and replace o-rings | |
2.Damaged seal under cylinder cap | Check and replace seal | |||
1.4 | Air leak in nose when tools are working | 1.Worn or damaged bumper | Check and replace bumper | |
2.Loose driver(piston unit) thread | Check and replace driver(piston unit) | |||
1.5 | Air leak in Trigger area when tools are working | 1.Worn or damaged trigger valve head | Check and replace trigger valve head | |
2.Damaged head valve piston o-rings | Check and replace head valve piston o-rings | |||
2 | Failed to get driver(piston unit) back to the correct position completely. | 1.The driver(piston unit) is not straight or the driver guide(nose) is wrong assembled. | Straighten the driver(piston unit) or verify driver guide(nose) and magazine | |
2.Worn or damaged nozzle | Check and replace nozzle | |||
3.The space between piston o-ring and cylinder is too tight. | Check if the cylinder is adequate lubrication or replace the o-ring on the piston. | |||
3 | Work weakly and sluggishly | 1. Worn or damaged piston o-ring | Check and replace piston o-ring | |
2.Inadequate lubrication for head valve piston o-rings or too tight head valve piston o-rings | Place 2 or 6 drops of oil on o-rings or replace head valve piston o-rings | |||
3.Dirt in the nozzle | Check and clean the nozzle | |||
4 | Tool jams frequently | 1.Damaged or Worn driver (piston unit) | Check and replace driver (piston unit) | |
2.Damaged or Worn driver guide (nose) | Check and replace driver guide (nose) | |||
3.Driver guide cover is bent,so the space between driver guide cover and driver guide is too big | Check and replace driver guide cover | |||
5 | Nail can not be shot | 1. Driver (piston unit) can't return to the correct position. | Refer to no. 1 Symptom | |
2.Driver guide(nose) can not match magazine well | Check and correct the position between driver guide(nose) and magazine | |||
3.Worn or damaged nail pusher compression spring | Check and replace nail pusher compression spring |