CN45 Pneumatic Coil Siding Nailer
Product Description
Product Overview: CN45 Pneumatic Coil Siding Nailer The CN45 Coil Siding Nailer is recommended for use in siding, fencing and decking applications. This air nailer features durable construction that is designed to help withstand job-site abuse over time. It optimizes productivity thanks to a lightweight design that helps minimize arm fatigue. This tool's powerful performance and tool-free depth of drive help flush drive 1 - 2 in. nails. ● Powerful tool drives nails into surfaces. ● Adjustable exhaust port for your convenience. ● Lightweight tool weighs only 3.50 lb. to help minimize arm fatigue. ● Durable construction for long-lasting use. |
Model: | CN45 Pneumatic Coil Siding Nailer |
Air Tool Type: | Air Nailer |
Tool Diamensions: | 248mmx108mmx260mm(11-1/8"x4-1/4"x10-1/8") |
Net Tool Weight: | 1.60kgs(3.50lbs) |
Body Material: | Aluminum Body |
Operate Pressure: | 70-120psi(5-8.3bar) |
Load Capacity: | 400 nails (Conical wire coil nails) |
200 nails (Plastic sheet collated nails) | |
Fasteners Type: | 15 Degree Conical wire coil nails |
15 Degree Flat plastic sheet collated nails | |
Fasteners Head Diameter: | 0.138"(3.5mm)-0.197"(5.0mm) |
Fasteners Shank Diameter: | 0.063"(1.59mm)-0.083"(2.1mm) |
Fasteners Length: | 1"(25mm)-2"(50mm) |
Fasteners Shank Type: | Smooth,Screw,Ring |
15 Degree Conical wire coil nails Head Diameter: 0.138"(3.5mm)-0.197"(5.0mm) Shank Diameter: 0.063"(1.59mm)-0.083"(2.1mm) Nail Length: 1"(25mm)-2"(50mm) Shank Type: Smooth ,Screw ,Ring, | 15 Degree Flat plastic sheet collated nails Head Diameter: 0.138"(3.5mm)-0.197"(5.0mm) Shank Diameter: 0.063"(1.59mm)-0.083"(2.1mm) Nail Length: 1"(25mm)-2"(50mm) Shank Type: Smooth ,Screw ,Ring, |
Strong and light weight aluminum body.
Soft grip handle for comfort and control,
Powerful high performance motor with adjustable exhaust diffuser.
Drives both conical wire welded and plastic sheet collated nails without any adjustment.
Adjustable firing mode and depth.
Sub-flooring
Fencing
Wall sheathing and roof sheating
Fastening gypsum board,decorative board and other interior boards.
No. | Symptom | Problems | Solutions | |
1.1 | Air Leak | Air leak in the cylinder cap when tools don't work | 1.Loose head valve piston seal or o-rings . | Check and replace the head valve piston set |
2.Worn or damaged o-ring or cylinder cap gasket under cylinder cap | Check and replace o-ring or cylinder cap gasket under the cylinder cap | |||
1.2 | Air leak in Trigger area when tools don't work | 1.Damaged o-ring in trigger valve | Check and replace o-ring | |
2.Damaged o-ring in trigger valve stem | Check and replace o-ring | |||
3.Dirt in the trigger valve | Check and clean the trigger valve | |||
1.3 | Air leak in cylinder cap when tools are working | 1.Damaged head valve piston o-rings | Check and replace o-rings | |
2.Damaged seal under cylinder cap | Check and replace seal | |||
1.4 | Air leak in nose when tools are working | 1.Worn or damaged bumper | Check and replace bumper | |
2.Loose driver(piston unit) thread | Check and replace driver(piston unit) | |||
1.5 | Air leak in Trigger area when tools are working | 1.Worn or damaged trigger valve head | Check and replace trigger valve head | |
2.Damaged head valve piston o-rings | Check and replace head valve piston o-rings | |||
2 | Failed to get driver(piston unit) back to the correct position completely. | 1.The driver(piston unit) is not straight or the driver guide(nose) is wrong assembled. | Straighten the driver(piston unit) or verify driver guide(nose) and magazine | |
2.Worn or damaged nozzle | Check and replace nozzle | |||
3.The space between piston o-ring and cylinder is too tight. | Check if the cylinder is adequate lubrication or replace the o-ring on the piston. | |||
3 | Work weakly and sluggishly | 1. Worn or damaged piston o-ring | Check and replace piston o-ring | |
2.Inadequate lubrication for head valve piston o-rings or too tight head valve piston o-rings | Place 2 or 6 drops of oil on o-rings or replace head valve piston o-rings | |||
3.Dirt in the nozzle | Check and clean the nozzle | |||
4 | Tool jams frequently | 1.Damaged or Worn driver (piston unit) | Check and replace driver (piston unit) | |
2.Damaged or Worn driver guide (nose) | Check and replace driver guide (nose) | |||
3.Driver guide cover is bent,so the space between driver guide cover and driver guide is too big | Check and replace driver guide cover | |||
5 | Nail can not be shot | 1. Driver (piston unit) can't return to the correct position. | Refer to no. 1 Symptom | |
2.Driver guide(nose) can not match magazine well | Check and correct the position between driver guide(nose) and magazine | |||
3.Worn or damaged nail pusher compression spring | Check and replace nail pusher compression spring |