1.0mm
KYA
KYA-TW1061T
| Surface Treatment: | |
|---|---|
| Availability: | |
| Quantity: | |
TW1061T 19 Gauge Twist Tie Wire is a double rebar tie wire designed for use with the MAX RB441T TwinTier rebar tying machine. It is used for tying rebar in precast concrete, foundations, road and bridge construction, floors, walls, retaining walls, swimming pool walls, radiant heating tubes, and electrical conduit fixing.
Made from low-carbon steel wire, TW1061T is available in black annealed wire, electro-galvanized wire, and polyester-coated wire. Each roll has a 1.0mm wire diameter, 33–34m double wire length, 0.45kg roll weight, and approximately 170–260 ties per coil, supporting efficient and consistent rebar tying on construction jobsites.

The TW1061T rebar tie wire is produced for stable feeding, reliable twisting, and efficient tying with the MAX RB441T TwinTier. Buyers should confirm wire diameter, roll length, material finish, tensile strength, and machine compatibility before ordering.
| Attribute | Details |
|---|---|
| Model | TW1061T Twist Tie Wire |
| Wire Diameter | 1.0mm / 19 Gauge |
| Wire Length | 33–34m double wire |
| Weight per Roll | 0.45kg |
| Material Options | Galvanized wire, black annealed wire, polyester-coated wire |
| Applicable Machine | MAX RB441T TwinTier |
| Ties per Coil | 170–260 ties |
| Wraps per Tie | 1 |
| Tensile Strength | 55,800–81,300 lb/in⊃2; / 385–560 MPa |
TW1061T is made from low-carbon steel wire with controlled chemical composition. This helps maintain stable wire strength, flexibility, and tying performance during automatic rebar tying operations.
| Carbon | Manganese | Phosphorus | Sulfur |
|---|---|---|---|
| 0.13–0.18% | 0.60–0.90% | Less than 0.03% | Less than 0.035% |


Different construction environments require different rebar tie wire finishes. KYA supplies TW1061T in black annealed, galvanized, and polyester-coated options to meet general construction, corrosion resistance, and harsh environment requirements.
| Wire Type | Recommended Use |
|---|---|
| Black Annealed Wire | General rebar tying, building foundations, floors, walls, and standard concrete reinforcement work |
| Electro-Galvanized Wire | Applications requiring improved corrosion resistance and cleaner surface protection |
| Polyester-Coated Wire | Harsh environments, marine areas, precast concrete, and projects with higher anti-corrosion requirements |
TW1061T is designed for automatic rebar tying efficiency. It supports fast tying, reduced wire usage, stable feeding, and a shorter tie height, helping contractors improve productivity and reduce manual tying labor.
Compatible with MAX RB441T TwinTier rebar tying machine.
1.0mm / 19 Gauge double wire for reliable automatic tying.
33–34m roll length with approximately 170–260 ties per coil.
Available in black annealed, electro-galvanized, and polyester-coated finishes.
Suitable for precast concrete, foundations, bridges, floors, walls, and retaining walls.
Designed to reduce wire usage with a shorter tie height.
Stable tensile strength range of 385–560 MPa for construction use.
TW1061T twist tie wire is widely used in concrete reinforcement projects where rebar needs to be tied quickly and consistently. It is suitable for contractors, precast concrete factories, infrastructure builders, rebar tying machine distributors, and construction material suppliers.
Precast concrete products and prefabricated concrete components.
Building foundations and concrete reinforcement structures.
Road and bridge construction.
Floors, walls, slabs, and retaining walls.
Swimming pool walls and reinforced concrete forms.
Radiant heating tubes and electrical conduit fixing.
Marine and harsh environment projects when using coated wire options.


When sourcing TW1061T tie wire, buyers should confirm machine model, wire finish, jobsite environment, corrosion resistance requirement, carton packing, and expected tying quantity. Choosing the correct finish helps reduce wire failure and improves project suitability.
| Selection Factor | Recommendation |
|---|---|
| Machine Compatibility | Confirm the tie wire will be used with MAX RB441T TwinTier. |
| Wire Finish | Choose black annealed, galvanized, or polyester-coated wire according to the application environment. |
| Corrosion Resistance | Use galvanized or polyester-coated wire for projects exposed to moisture, harsh conditions, or marine environments. |
| Tying Quantity | Estimate consumption based on approximately 170–260 ties per coil. |
| Project Type | Select wire based on foundations, precast concrete, slabs, walls, bridge work, or infrastructure projects. |
KYA Fasteners supplies rebar tie wire, automatic rebar tying machine wire, industrial fasteners, construction fastening products, and related tools for global distributors, contractors, precast factories, and infrastructure project buyers.
TW1061T 19 Gauge tie wire for MAX RB441T TwinTier applications.
Black annealed, galvanized, and polyester-coated wire options available.
Suitable for construction contractors, precast concrete factories, rebar tier distributors, and building material suppliers.
Support for bulk orders, project supply, and matched rebar tying tool sourcing.
One-stop supply of rebar tie wire and rebar tying tools.
TW1061T Twist Tie Wire is used with the MAX RB441T TwinTier rebar tying machine for tying rebar in precast concrete, foundations, road and bridge construction, floors, walls, retaining walls, swimming pools, radiant heating tubes, and conduit fixing.
TW1061T tie wire is designed for the MAX RB441T TwinTier rebar tying machine. Buyers should confirm machine model compatibility before placing an order.
The TW1061T wire diameter is 1.0mm, equal to 19 Gauge. Each roll contains 33–34m of double wire and weighs approximately 0.45kg.
One TW1061T coil can make approximately 170–260 ties. The actual number of ties depends on rebar size, tying position, machine setting, and application conditions.
TW1061T is available in black annealed wire, electro-galvanized wire, and polyester-coated wire. These options support different construction environments and corrosion resistance requirements.
Yes. Electro-galvanized wire and polyester-coated wire provide better corrosion resistance for moisture exposure, marine environments, precast concrete work, and other demanding construction conditions.
The tensile strength range is 55,800–81,300 lb/in⊃2;, equal to 385–560 MPa. This strength range supports durable tying performance in concrete reinforcement applications.
Bulk buyers include construction contractors, rebar tying machine distributors, precast concrete factories, bridge contractors, infrastructure project suppliers, and building material wholesalers.
FURNITURE ACCESSORIES
OFFICE SUPPLIES
PACKAGING MATERIAL