F30
KYA
KYA-F30
1.10kgs
60-100psi (4-7bar)
100 Nails
18 Guage F Brad Nails
Availability: | |
---|---|
Quantity: | |
18 Gauge Pneumatic Brad Nailer F3018 Gauge Pneumatic Brad Nailer F30 ideal for a wide variety of finish applications, Designed with a aluminum body for strength and lightweight use. ● Tool-free depth-of-drive adjustment. ● Tool-free jam release. ● Drives 3/8 in. to 1-3/16 in. 18 guage F brad nails. ● High capacity magazine holds up to 100 nails. ● Lightweight aluminum alloy body weighs only 2.4 pounds. |
Model: | 18 Gauge Pneumatic Brad Nailer F30 |
Air Tool Type: | Air Nailer |
Tool Diamensions: | 197mm x 57mm x 235mm |
Net Tool Weight: | 1.10kgs(2.42 lbs) |
Body Material: | Aliminum Body |
Operate Pressure: | 60-100psi (4-7bar) |
Load Capacity: | 100 nails |
Nails Type: | 18 Guage F Brad Nails |
Nails Head Diameter: | 0.075"(1.9mm) x 0.050"(1.3mm) |
Nails Shank Diameter: | 1.05mm |
Nails Length: | 3/8"(10mm)~1-3/16"(30mm) |
18 Guage F Brad Nails |
Nails Head Diameter:0.075"(1.9mm) x 0.050"(1.3mm) |
Nails Shank Diameter:1.05mm |
Nails Length:3/8"(10mm)~1-3/16"(30mm) |
Lightweight and well balanced for easy operating.
Superior power with hardened one piece piston for professional application.
Open nose design for easy extraction of a jammed nail.
Tool free depth of drive adjustment for flush or counter sunk drive into varying material.
Hardened claw tip,reduces wear and limits slippage when driving at a stand angle.
Decorative and furniture trim.
Picture frame assembly.
Interior and exterior trim.
Cabinet work.
Upholstery and bedding.
Crafts.
No. | Symptom | Problems | Solutions | |
1.1 | Air Leak | Air leak in the cylinder cap when tools don't work | 1.Loose head valve piston seal or o-rings . | Check and replace the head valve piston set |
2.Worn or damaged o-ring or cylinder cap gasket under cylinder cap | Check and replace o-ring or cylinder cap gasket under the cylinder cap | |||
1.2 | Air leak in Trigger area when tools don't work | 1.Damaged o-ring in trigger valve | Check and replace o-ring | |
2.Damaged o-ring in trigger valve stem | Check and replace o-ring | |||
3.Dirt in the trigger valve | Check and clean the trigger valve | |||
1.3 | Air leak in cylinder cap when tools are working | 1.Damaged head valve piston o-rings | Check and replace o-rings | |
2.Damaged seal under cylinder cap | Check and replace seal | |||
1.4 | Air leak in nose when tools are working | 1.Worn or damaged bumper | Check and replace bumper | |
2.Loose driver(piston unit) thread | Check and replace driver(piston unit) | |||
1.5 | Air leak in Trigger area when tools are working | 1.Worn or damaged trigger valve head | Check and replace trigger valve head | |
2.Damaged head valve piston o-rings | Check and replace head valve piston o-rings | |||
2 | Failed to get driver(piston unit) back to the correct position completely. | 1.The driver(piston unit) is not straight or the driver guide(nose) is wrong assembled. | Straighten the driver(piston unit) or verify driver guide(nose) and magazine | |
2.Worn or damaged nozzle | Check and replace nozzle | |||
3.The space between piston o-ring and cylinder is too tight. | Check if the cylinder is adequate lubrication or replace the o-ring on the piston. |
18 Gauge Pneumatic Brad Nailer F3018 Gauge Pneumatic Brad Nailer F30 ideal for a wide variety of finish applications, Designed with a aluminum body for strength and lightweight use. ● Tool-free depth-of-drive adjustment. ● Tool-free jam release. ● Drives 3/8 in. to 1-3/16 in. 18 guage F brad nails. ● High capacity magazine holds up to 100 nails. ● Lightweight aluminum alloy body weighs only 2.4 pounds. |
Model: | 18 Gauge Pneumatic Brad Nailer F30 |
Air Tool Type: | Air Nailer |
Tool Diamensions: | 197mm x 57mm x 235mm |
Net Tool Weight: | 1.10kgs(2.42 lbs) |
Body Material: | Aliminum Body |
Operate Pressure: | 60-100psi (4-7bar) |
Load Capacity: | 100 nails |
Nails Type: | 18 Guage F Brad Nails |
Nails Head Diameter: | 0.075"(1.9mm) x 0.050"(1.3mm) |
Nails Shank Diameter: | 1.05mm |
Nails Length: | 3/8"(10mm)~1-3/16"(30mm) |
18 Guage F Brad Nails |
Nails Head Diameter:0.075"(1.9mm) x 0.050"(1.3mm) |
Nails Shank Diameter:1.05mm |
Nails Length:3/8"(10mm)~1-3/16"(30mm) |
Lightweight and well balanced for easy operating.
Superior power with hardened one piece piston for professional application.
Open nose design for easy extraction of a jammed nail.
Tool free depth of drive adjustment for flush or counter sunk drive into varying material.
Hardened claw tip,reduces wear and limits slippage when driving at a stand angle.
Decorative and furniture trim.
Picture frame assembly.
Interior and exterior trim.
Cabinet work.
Upholstery and bedding.
Crafts.
No. | Symptom | Problems | Solutions | |
1.1 | Air Leak | Air leak in the cylinder cap when tools don't work | 1.Loose head valve piston seal or o-rings . | Check and replace the head valve piston set |
2.Worn or damaged o-ring or cylinder cap gasket under cylinder cap | Check and replace o-ring or cylinder cap gasket under the cylinder cap | |||
1.2 | Air leak in Trigger area when tools don't work | 1.Damaged o-ring in trigger valve | Check and replace o-ring | |
2.Damaged o-ring in trigger valve stem | Check and replace o-ring | |||
3.Dirt in the trigger valve | Check and clean the trigger valve | |||
1.3 | Air leak in cylinder cap when tools are working | 1.Damaged head valve piston o-rings | Check and replace o-rings | |
2.Damaged seal under cylinder cap | Check and replace seal | |||
1.4 | Air leak in nose when tools are working | 1.Worn or damaged bumper | Check and replace bumper | |
2.Loose driver(piston unit) thread | Check and replace driver(piston unit) | |||
1.5 | Air leak in Trigger area when tools are working | 1.Worn or damaged trigger valve head | Check and replace trigger valve head | |
2.Damaged head valve piston o-rings | Check and replace head valve piston o-rings | |||
2 | Failed to get driver(piston unit) back to the correct position completely. | 1.The driver(piston unit) is not straight or the driver guide(nose) is wrong assembled. | Straighten the driver(piston unit) or verify driver guide(nose) and magazine | |
2.Worn or damaged nozzle | Check and replace nozzle | |||
3.The space between piston o-ring and cylinder is too tight. | Check if the cylinder is adequate lubrication or replace the o-ring on the piston. |